{"id":2261,"date":"2021-02-10T07:07:36","date_gmt":"2021-02-10T07:07:36","guid":{"rendered":"https:\/\/www.emcfastpass.com\/test-equipment\/?post_type=product&#038;p=2261"},"modified":"2023-02-01T22:10:33","modified_gmt":"2023-02-01T22:10:33","slug":"used-ets-lindgren-fact-3-chamber-test-lab-equipment","status":"publish","type":"product","link":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/","title":{"rendered":"Used ETS Lindgren FACT 3 Chamber &#038; Test Lab Equipment"},"content":{"rendered":"<p>Very high-spec 3-meter compliant EMC chamber that we recently acquired from an academic facility. Originally installed in 2008, the chamber has been lightly used and is in great condition.<\/p>\n<p>Located in the US, the chamber was professionally dismantled in Feb 2021. Currently in warehousing in South Carolina.<\/p>\n<p>A full suite of lightly used emissions and immunity test equipment is also available separately (details below).<\/p>\n<p>The facility is capable of simulating the conditions of most commercial automotive EMC test procedures while also supporting compliant FCC and CISPR EMC tests, antenna measurements, model validation and research projects at frequencies from DC to several GHz and higher.<\/p>\n<h3>Key Features<\/h3>\n<ul>\n<li>Radiated Emission 30 MHz &#8211; 18 GHz Compliant<\/li>\n<li>Radiated Immunity 26 MHz &#8211; 18 GHz Compliant (with floor absorber)<\/li>\n<li>2m quiet zone<\/li>\n<li>FCC and CISPR compliant test site<\/li>\n<li>&#8216;Premium&#8217; model: significantly better than +\/-4dB NSA requirement<\/li>\n<li>Heavy-duty 2 m diameter turntable with a 1,497 kg distributed load capacity<\/li>\n<li>Fully automatic pneumatically operated Euroshield sliding equipment door, measuring 2.1 m x 2.4 m, featuring a flush sill to facilitate push button entry\/egress<\/li>\n<li>Hybrid absorber treatment on all wall and ceiling surfaces<\/li>\n<li>Full ferrite coverage on walls and ceiling<\/li>\n<li>Chamber designed for certification with normalized site attenuation per FCC, Part 15, 3 m measurements<\/li>\n<li>Testing in accordance with IEC61000-4-3, EN 50147-2 and ANSI C63.4 from 30 MHz to 18 GHz for automotive EMC radiated emissions and immunity testing<\/li>\n<li>Original specifications and drawings available<\/li>\n<\/ul>\n<h3>Chamber Dimensions<\/h3>\n<p><strong>Internal Dimensions (L x W x H): <\/strong><\/p>\n<p>8.53 x 6.10 x 5.49 m (28.0 x 20.0 x 18.0 ft) Internal shield to shield (Excluding the raised floor)<\/p>\n<p><strong>Outer Dimensions (L x W x H):<\/strong><\/p>\n<p>9.02 x 6.34 x 6.73 m (29.58 x 22.08 x 22.08 ft) Exterior with structural frame<\/p>\n<h4>Test Equipment<\/h4>\n<p>Included equipment:<\/p>\n<ul>\n<li>ETS Lindgren Model 2181-2.03 electric, heavy duty turntable<\/li>\n<li>ETS Lindgren Model 2175 Antenna Tower (4m)<\/li>\n<li>ETS Lindgren Model 2175 MiniMast II&#x2122;<\/li>\n<li>ETS Lindgren Model 2090 dual device controller<\/li>\n<li>ETS Lindgren Model 3142C Biconilog antenna (26 MHz to 3.0 GHz)<\/li>\n<li>ETS Lindgren Model 4340 CCTV Monitoring System<\/li>\n<li>Large Euroshield door with flush entry<\/li>\n<li>CISPR 25 test table<\/li>\n<li>Installation included<\/li>\n<\/ul>\n<h4>Optional Equipment (available at additional cost)<\/h4>\n<p>The facility utilized a large amount of test equipment. We would consider selling the equipment as a package, or after a period of time, we will begin to offer individual pieces listed below:<\/p>\n<p><strong>Receivers\/Analyzers<\/strong><\/p>\n<ul>\n<li>Rohde &amp; Schwarz ESU-8 Receiver<\/li>\n<li>Rohde &amp; Schwarz EMC32 measurement automation software<\/li>\n<\/ul>\n<p><strong>Amplifiers<\/strong><\/p>\n<ul>\n<li>Amplifier Research 150A100BM1 (150W 10 kHz &#8211; 100 MHz for conducted immunity testing)<\/li>\n<li>Amplifier Research 500W1000AM7 (500W 30 MHz &#8211; 1000 MHz for radiated immunity testing)<\/li>\n<\/ul>\n<p><strong>Antennae:<\/strong><\/p>\n<ul>\n<li>ETS Lindgren 3116 horn antenna<\/li>\n<li>ETS Lindgren 3117 horn antenna<\/li>\n<li>ETS Lindgren 3106B horn antenna<\/li>\n<li>ETS Lindgren 3110B antenna<\/li>\n<li>ETS Lindgren 3148 antenna<\/li>\n<\/ul>\n<p><strong>Transient Equipment:<\/strong><\/p>\n<ul>\n<li>EMC Partner TRA2000 combination immunity test generator<\/li>\n<li>EMC Partner ESD3000 ESD Simulator (30kV)<\/li>\n<li>EMC Partner CN-EFT1000 capacitive clamp<\/li>\n<li>EMC Partner CDN-KIT1000 CDN kit<\/li>\n<\/ul>\n<p><strong>Current Probes:<\/strong><\/p>\n<ul>\n<li>Fischer Custom Communication F-150<\/li>\n<li>Fischer Custom Communication F-10<\/li>\n<li>Fischer Custom Communication F-61 (x2)<\/li>\n<li>Fischer Custom Communication F2000<\/li>\n<li>Fischer Custom Communication calibration fixture FCC-BCICF-1<\/li>\n<\/ul>\n<p><strong>Additional Pieces:<\/strong><\/p>\n<ul>\n<li>R&amp;S NRP power meter<\/li>\n<li>HI6105 laser powered isotropic field probe (100 kHz &#8211; 6 GHz)<\/li>\n<li>HI6100 field monitor<\/li>\n<\/ul>\n<p><strong>Accessories:<\/strong><\/p>\n<p>Various other accessories (to be added)<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Relocation &amp; Installation<\/strong><\/p>\n<p>We can relocate this chamber within USA, Canada or Mexico. Full installation services provided.<\/p>\n<p>If you would like to discuss this chamber with us, please email <a href=\"mailto:andy@emcfastpass.com\">andy@emcfastpass.com<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Rare opportunity to purchase a pre-owned 3m EMC chamber for compliant FCC\/CISPR emissions and immunity testing. Recovered from academic environment. Everything in mint condition, ready for relocation to your facility.<\/p>\n","protected":false},"featured_media":2264,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[80],"product_tag":[],"class_list":{"0":"post-2261","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-anechoic-chambers","8":"first","9":"outofstock","10":"sold-individually","11":"taxable","12":"shipping-taxable","13":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Used ETS Lindgren FACT 3 Chamber &amp; Test Lab Equipment - EMC Chambers &amp; Test Equipment<\/title>\n<meta name=\"description\" content=\"Rare pre-owned 3m EMC chamber for compliant FCC\/CISPR emissions and immunity testing available for sale. Mint condition, ready for relocation\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Used ETS Lindgren FACT 3 Chamber &amp; Test Lab Equipment - EMC Chambers &amp; Test Equipment\" \/>\n<meta property=\"og:description\" content=\"Rare pre-owned 3m EMC chamber for compliant FCC\/CISPR emissions and immunity testing available for sale. Mint condition, ready for relocation\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/\" \/>\n<meta property=\"og:site_name\" content=\"EMC Chambers &amp; Test Equipment\" \/>\n<meta property=\"article:modified_time\" content=\"2023-02-01T22:10:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2021\/02\/3m_FCC_CISPR_chamber.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1008\" \/>\n\t<meta property=\"og:image:height\" content=\"756\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/\",\"url\":\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/\",\"name\":\"Used ETS Lindgren FACT 3 Chamber & Test Lab Equipment - EMC Chambers &amp; Test Equipment\",\"isPartOf\":{\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2021\/02\/3m_FCC_CISPR_chamber.jpg\",\"datePublished\":\"2021-02-10T07:07:36+00:00\",\"dateModified\":\"2023-02-01T22:10:33+00:00\",\"description\":\"Rare pre-owned 3m EMC chamber for compliant FCC\/CISPR emissions and immunity testing available for sale. Mint condition, ready for relocation\",\"breadcrumb\":{\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#primaryimage\",\"url\":\"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2021\/02\/3m_FCC_CISPR_chamber.jpg\",\"contentUrl\":\"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2021\/02\/3m_FCC_CISPR_chamber.jpg\",\"width\":1008,\"height\":756,\"caption\":\"anechoic chamber emc testing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.emcfastpass.com\/test-equipment\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Shop\",\"item\":\"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Used ETS Lindgren FACT 3 Chamber &#038; Test Lab Equipment\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/#website\",\"url\":\"https:\/\/www.emcfastpass.com\/test-equipment\/\",\"name\":\"EMC Chambers &amp; Test Equipment\",\"description\":\"EMC Test Equipment Sales, Reviews and Tutorials\",\"publisher\":{\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.emcfastpass.com\/test-equipment\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/#organization\",\"name\":\"EMC Chambers &amp; Test Equipment\",\"url\":\"https:\/\/www.emcfastpass.com\/test-equipment\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2023\/11\/EMC-logo.png\",\"contentUrl\":\"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2023\/11\/EMC-logo.png\",\"width\":262,\"height\":70,\"caption\":\"EMC Chambers &amp; Test Equipment\"},\"image\":{\"@id\":\"https:\/\/www.emcfastpass.com\/test-equipment\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.youtube.com\/@EMCFastPass\/videos\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Used ETS Lindgren FACT 3 Chamber & Test Lab Equipment - EMC Chambers &amp; Test Equipment","description":"Rare pre-owned 3m EMC chamber for compliant FCC\/CISPR emissions and immunity testing available for sale. Mint condition, ready for relocation","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/","og_locale":"en_US","og_type":"article","og_title":"Used ETS Lindgren FACT 3 Chamber & Test Lab Equipment - EMC Chambers &amp; Test Equipment","og_description":"Rare pre-owned 3m EMC chamber for compliant FCC\/CISPR emissions and immunity testing available for sale. Mint condition, ready for relocation","og_url":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/","og_site_name":"EMC Chambers &amp; Test Equipment","article_modified_time":"2023-02-01T22:10:33+00:00","og_image":[{"width":1008,"height":756,"url":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2021\/02\/3m_FCC_CISPR_chamber.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/","url":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/","name":"Used ETS Lindgren FACT 3 Chamber & Test Lab Equipment - EMC Chambers &amp; Test Equipment","isPartOf":{"@id":"https:\/\/www.emcfastpass.com\/test-equipment\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#primaryimage"},"image":{"@id":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#primaryimage"},"thumbnailUrl":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2021\/02\/3m_FCC_CISPR_chamber.jpg","datePublished":"2021-02-10T07:07:36+00:00","dateModified":"2023-02-01T22:10:33+00:00","description":"Rare pre-owned 3m EMC chamber for compliant FCC\/CISPR emissions and immunity testing available for sale. Mint condition, ready for relocation","breadcrumb":{"@id":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#primaryimage","url":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2021\/02\/3m_FCC_CISPR_chamber.jpg","contentUrl":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2021\/02\/3m_FCC_CISPR_chamber.jpg","width":1008,"height":756,"caption":"anechoic chamber emc testing"},{"@type":"BreadcrumbList","@id":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/chambers-shielded-rooms\/anechoic-chambers\/used-ets-lindgren-fact-3-chamber-test-lab-equipment\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.emcfastpass.com\/test-equipment\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/www.emcfastpass.com\/test-equipment\/shop\/"},{"@type":"ListItem","position":3,"name":"Used ETS Lindgren FACT 3 Chamber &#038; Test Lab Equipment"}]},{"@type":"WebSite","@id":"https:\/\/www.emcfastpass.com\/test-equipment\/#website","url":"https:\/\/www.emcfastpass.com\/test-equipment\/","name":"EMC Chambers &amp; Test Equipment","description":"EMC Test Equipment Sales, Reviews and Tutorials","publisher":{"@id":"https:\/\/www.emcfastpass.com\/test-equipment\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.emcfastpass.com\/test-equipment\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.emcfastpass.com\/test-equipment\/#organization","name":"EMC Chambers &amp; Test Equipment","url":"https:\/\/www.emcfastpass.com\/test-equipment\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.emcfastpass.com\/test-equipment\/#\/schema\/logo\/image\/","url":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2023\/11\/EMC-logo.png","contentUrl":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-content\/uploads\/2023\/11\/EMC-logo.png","width":262,"height":70,"caption":"EMC Chambers &amp; Test Equipment"},"image":{"@id":"https:\/\/www.emcfastpass.com\/test-equipment\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.youtube.com\/@EMCFastPass\/videos"]}]}},"_links":{"self":[{"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/product\/2261","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/comments?post=2261"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/media\/2264"}],"wp:attachment":[{"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/media?parent=2261"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/product_brand?post=2261"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/product_cat?post=2261"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.emcfastpass.com\/test-equipment\/wp-json\/wp\/v2\/product_tag?post=2261"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}